DynaPro® Finger Flex WHFO

From OCSI | HCPCS: L3807, L3809

a56b89d3-96b1-4160-af48-2acfc4caa398
ac201b37-c4dd-4fda-a836-7b3ff16290cd
finger flex flexing
a56b89d3-96b1-4160-af48-2acfc4caa398 thumbnail
ac201b37-c4dd-4fda-a836-7b3ff16290cd thumbnail
finger flex flexing thumbnail
×
1 / 3
a56b89d3-96b1-4160-af48-2acfc4caa398
2 / 3
ac201b37-c4dd-4fda-a836-7b3ff16290cd
3 / 3
finger flex flexing

a56b89d3-96b1-4160-af48-2acfc4caa398 thumbnailac201b37-c4dd-4fda-a836-7b3ff16290cd thumbnailfinger flex flexing thumbnail

Static/Flex Neuro-Dynamic Therapy  View more

Product Information Request

Ideal “static / dynamic” neuro-inhibiting therapy in a resting hand design with a heat moldable flexible insert that “flexes” at the wrist, MCP and PIP joints of the fingers to accommodate spastic episodes of tone and can be heat molded to “flex” into the contracted joint(s) to provide a therapeutic neuro-inhibiting stretch. 

The DynaPro® Finger Flex is a resting hand design with a thermoplastic insert that is heat molded approximately 15 to 30 degrees “ahead” of comfortable end range stretch at the wrist (i.e., with wrist contracture of 45 degrees, the insert is heat molded to – 30 to -15° degrees). The finger pan should be heat molded to maintain the fingers in optimal extension. When applied, the flexible insert will “flex” into the wrist contracture applying a therapeutic, inhibiting stretch on the shortened tissue at the wrist and the fingers. The gentle tension applied by the correctly heat molded insert will provide abnormal reflex arc therapy to reduce abnormal tone over time as well as lengthening shortened tissue. As wrist extension is improved, the fingers will also open incrementally farther. The device should be modified by heat molding the insert every 6 to 8 weeks to continue contracture reversal (i.e., when the wrist improves from – 45 to -30, the insert must be heat molded to – 15 to neutral to continue the “flex” therapy). By increasing wearing time to three to six hours per use, the Total End Range Time (TERT) of device wear provides long effects stretch and permanent increases in joint range of motion over time. Orthotic treatment should be continued until function is restored to the affected hand.

FEATURES AND BENEFITS

  • Static/Flex Neuro-Dynamic Therapy
  • Color Coded Straps
  • Resting hand design with flexible finger platform
  • Flexible wrist, MCP and PIP insert minimizes spastic episodes
  • Finger separators included

SIZES

Prod Spec Prod Spec Value
Child Width of MP Joints 1.75" - 2" / Length 8.25"
Youth Width of MP Joints 2 " -2.5" / Length 10 .25"
Small Width of MP Joints 2.5"- 3" / Length 11.25"
Medium Width of MP Joints 3" - 3.5" / Length 12.25"
Large Width of MP Joints 3.5" - 4" / Length 13.25"

PRODUCT CODES

Prod Spec Prod Spec Value
DP WFF-24C (left or right) Child
DP WFF-25Y (left or right) Youth
DP WFF-21S (left or right) Small
DP WFF-22M (left or right) Medium
DP WFF-23L (left or right) Large
  • Static/Flex Neuro-Dynamic Therapy
  • Color Coded Straps
  • Resting hand design with flexible finger platform
  • Flexible wrist, MCP and PIP insert minimizes spastic episodes

Customer Reviews